zanussi ZWD1680W Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › zanussi ZWD1680W This topic has 2 replies, 3 voices, and was last updated 17 years ago by LittleMan. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts April 4, 2009 at 1:54 pm #44766 LittleManParticipant Hi This washer dryer will flash e10 after about 10 min on drying prog could this be the condensor inlet valve can any one help please Many thanks Les April 4, 2009 at 3:36 pm #282239 Specialist01269Participant Re: zanussi ZWD1680W Hi: E10 is the user error code for cycle paused, due to any of the following: 1) Poor water pressure 2) Faulty inlet valve 3) Fault in pressure system or switch 4) Bad interconnection wiring 5) PCB faulty Normally in that order, HTH[/img] April 4, 2009 at 5:48 pm #282240 leavemetogetonwithitParticipant Re: zanussi ZWD1680W The coils on these valves can measure OK when you check them but go o/c when they warm up. Common problem; must be ’cause I’ve seen it twice. Mike. Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In