Hotpoint TDC62

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #44869
    rocker
    Participant

    I have twice replaced the thermostats within 3days, have cleaned all usual parts, rear fan turning ok, filters clean, no obvious cause, can anyone please advise.
    john.

    #282683
    bazza500
    Participant

    Re: Hotpoint TDC62

    Is the customer opening the door before the end of the cycle therefore missing out the 10 min cooling period?

    #282684
    johnnyj
    Participant

    Re: Hotpoint TDC62

    If everything checks it could be the dryness module not switching the heater off when it reverses causing the stats to trip.

    #282685
    boselecta
    Participant

    Got to be worth putting a capacitor in. The cap may working when tested but when they are loosing charge, getting faulty with a wet load in they can just just hum casing the stat to trip out.

    #282686
    rocker
    Participant

    Re: Hotpoint TDC62

    thanks for replys gents, customer is not opening door, how do you test dryness module !!! can someone please let me know. john

    #282687
    iadom
    Moderator

    Re: Hotpoint TDC62

    Switch the selector knob on, if the heat light is lit before you press the start button then the module is faulty, or set it on and wait untli it does the short reverse (anti clockwise) tumble. If the light does not go out then its the module.

    The module is quite expensive and sadly EMW/QER do not repair these. Not heard of anyone who has successfully replaced a heater relay on one of these boards yet either. According to Tony at EMW the processor is usually corrupted when the relay fails. 😥

    Jim.

    #282688
    rocker
    Participant

    Re: Hotpoint TDC62

    Jim, Many thanks for your advice . John

Viewing 7 posts - 1 through 7 (of 7 total)