Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › neff s5543x1 dishwasher
- This topic has 13 replies, 7 voices, and was last updated 16 years, 11 months ago by
suedehead1.
-
AuthorPosts
-
April 15, 2009 at 9:37 pm #45015
suedehead1
Participanthi,
the dishwasher wont fill up, the customer had installed a new washing machine but turned the water off to the dishwasher, after leaving it on for 8 hours he realised it wasnt working but when he turned the water on it wont fill.
its one of these fill hoses with the solenoid at the valve end, the solenoid is ok but it wont fill up the valve isnt getting electricity, i checked everything but it wont fill any ideas?April 16, 2009 at 7:40 am #283288Martin
ParticipantRe: neff s5543x1 dishwasher
8hrs? …… Probably inlet valve burnt out I should imagine?
April 16, 2009 at 9:09 pm #283289suedehead1
ParticipantRe: neff s5543x1 dishwasher
i checked the valve and it was ok.
April 16, 2009 at 10:18 pm #283290leavemetogetonwithit
ParticipantRe: neff s5543x1 dishwasher
suedehead1 wrote:the valve isnt getting electricity
I think you’ve got an “Aquastop”? Give lots of trouble. Have you tried a search using the forum search engine and the above term?
IIRC the supply to the valve in the aquastop is governed by a pressure switch or some such anti-flood device.
Mike.April 17, 2009 at 7:50 am #283291Martin
ParticipantRe: neff s5543x1 dishwasher
suedehead1 wrote:the valve isnt getting electricity,
Ooops just spotted this. 😳
No power to valve will probably mean that the triac to the valve on the PCB has gone west? 🙁
April 17, 2009 at 10:13 am #283292cornwell40
ParticipantRe: neff s5543x1 dishwasher
Would it not time out before any big problems arose? 😕
TC
April 22, 2009 at 6:59 pm #283293suedehead1
ParticipantRe: neff s5543x1 dishwasher
this triac to the valve is it replaceable?
April 23, 2009 at 7:44 am #283294Martin
ParticipantRe: neff s5543x1 dishwasher
No. 🙁
May 4, 2009 at 6:39 pm #283295suedehead1
ParticipantRe: neff s5543x1 dishwasher
hi,
i sent the board to qer for repair it has came back with a couple of triacs replaced on it. i connected it up and there was a pop and one of the triacs has blown i am sending it back for repair but i was wondering why it has blown the triac.May 4, 2009 at 8:44 pm #283296deltra
ParticipantRe: neff s5543x1 dishwasher
ask what the triacs are controling,valve,heater etc? that will be where the fault is.
May 4, 2009 at 11:43 pm #283297Penguin45
ParticipantRe: neff s5543x1 dishwasher
Use a meter. Follow the tracks back to the edge connector. Wherever that goes, there’s your problem.
Chris.
May 5, 2009 at 5:23 pm #283298suedehead1
ParticipantRe: neff s5543x1 dishwasher
the triac is controling the water valve but it tested ok.
May 5, 2009 at 5:29 pm #283299Simon46
ParticipantRe: neff s5543x1 dishwasher
Would replace solenoid coil or wvalve. must be going short cct with mains applied.
S.
May 12, 2009 at 5:20 pm #283300suedehead1
ParticipantRe: neff s5543x1 dishwasher
i got the pcb back for qer with an exernal fault note that they had forgotten to tell me the solenoid valve was faulty i changed it and refitted the pcb and it worked ok fingers crossed.
-
AuthorPosts
- You must be logged in to reply to this topic.