Bosch T/D WTE84102/GB05

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #45631
    silverbroom
    Participant

    Prior to visiting this tumble dryer (Wednesday), lady say’s the dryer goes for a few minutes then stops with the drying and anti-crease lights flashing.

    Anyone have fault codes for this model most appreciated.

    thanks

    silverbroom

    #286413
    BSH-MAN
    Participant

    Re: Bosch T/D WTE84102/GB05

    From memory, it’s the element NTC out of range.

    #286414
    silverbroom
    Participant

    Re: Bosch T/D WTE84102/GB05

    Thanks for that, at least I know where to start.


    silverbroom

    #286415
    Phidom
    Participant

    Re: Bosch T/D WTE84102/GB05

    I went to one of these today. It runs for about a minute then goes dead, no lights lit or flashing. I tried bypassing the TOC on the heater but that made no difference. It will sometimes come on again after a minute or two, sometimes longer. There is a small PCB with a relay, mounted on the side at the top of the machine. I assume this must control the heater, as the motor still runs with the 2 thick wires to the board disconnected. With these wires off it still cuts out after about a minute. Any suggestions?

Viewing 4 posts - 1 through 4 (of 4 total)
  • You must be logged in to reply to this topic.