Hotpoint DWF70P THERMOSTAT

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #45800
    Latham63
    Participant

    Have replaced heater on this machine.AL10(heater circuit) code still flashing?
    Cant find TOC or thermostats on this one.
    Does the small pcb (top left on facia) control heater?

    #287099
    spimps
    Participant

    Re: Hotpoint DWF70P THERMOSTAT

    AL10=
    Check heater
    Check heater cut out
    Check pressure switch connections 11-14 heater supplied via these
    check wiring and connections between module,pressure switch and heater if yopu have supply through heater it could be the relay on module.
    Make sure all filters are clean as there is a sensor which will operate if they are blocked,supposed to be self cleaning 😕
    Plus give all connections onto the module a tweek and the thermistor one too.
    BG

    #287100
    iadom
    Moderator

    Re: Hotpoint DWF70P THERMOSTAT

    Latham63 wrote:
    Cant find TOC or thermostats on this one.

    Its hard wired to the PCB and slots into a clip on the inner door panel.

Viewing 3 posts - 1 through 3 (of 3 total)