Bendix BIW125W Only Pumps Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Bendix BIW125W Only Pumps This topic has 3 replies, 3 voices, and was last updated 16 years, 8 months ago by neilsukwg. Viewing 4 posts - 1 through 4 (of 4 total) Author Posts July 17, 2009 at 9:32 am #47143 neilsukwgParticipant Got this bendix machine that will only pump on all positions Lights on are Prewash and door lock Pressure switch does not seem stuck and there is no anti flood device. Is it the main PCB? or am i missing something.. July 17, 2009 at 1:00 pm #292453 LJDomesticsParticipant Re: Bendix BIW125W Only Pumps tried pulling the pressure hose off? if u here it click if u do then try blowing down the tube itself. July 17, 2009 at 1:40 pm #292454 wilfParticipant Re: Bendix BIW125W Only Pumps check the resistance of the valve if the pump is used as a ballast for the valve a short valve would run the pump. wilf July 17, 2009 at 4:21 pm #292455 neilsukwgParticipant Re: Bendix BIW125W Only Pumps Tried the pressure switch, but not checked the inlet valves. Thanks, will check that. Neil Author Posts Viewing 4 posts - 1 through 4 (of 4 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In