HOTPOINT FFA74G Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › HOTPOINT FFA74G This topic has 3 replies, 2 voices, and was last updated 16 years, 8 months ago by kevinlewis. Viewing 4 posts - 1 through 4 (of 4 total) Author Posts July 21, 2009 at 2:40 pm #47235 kevinlewisParticipant HEY GUYS WONDERING IF YOU CAN HELP FRIDGE OVERCOOLING FREEZER NOT COOLING AT ALL IVE TESTED: SENSORS TESTED OK IN SERVICE MODE PCB SHOWS NO VISIBLE DAMAGE DIVERTER COIL CONTINUITY OK ANYIDEAS? THANKS July 21, 2009 at 6:40 pm #292777 johnnyjParticipant Re: HOTPOINT FFA74G System fault by the sound of it, they are prone to leaks from the anticondensation loop around the freezer door. jj August 10, 2009 at 3:20 pm #292778 kevinlewisParticipant CUSTOMER NOW SAYS FRIDGE GONE OFF, SO IT SEEMS YOU’R CORRECT THERE IS A LEAK.IS THE CONDENSATION COIL REPAIRABLE OR IS THERE A MODIFICATION?, August 10, 2009 at 4:47 pm #292779 johnnyjParticipant Re: HOTPOINT FFA74G You can bypass it but more than likely a call back with a complaint of condesation around the freezer. Author Posts Viewing 4 posts - 1 through 4 (of 4 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In