Smeg d/w DWF410SS

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #49528
    senseib
    Participant

    This m/c will start the programme then after a couple of minutes error code E9 appears (water in base according to book) but still does it with the base off – no sign of any water anywhere in base!


    Any thoughts 😕

    Brian.

    #300161
    clivejameson
    Participant

    Re: Smeg d/w DWF410SS

    Has it had a leak of any sort and jammed the float switch up or created an earth fault?

    #300162
    Penguin45
    Participant

    Re: Smeg d/w DWF410SS

    Repetative overfill. Can be p/sw; more likely pcb not turning off valve. Had one recently with blown suppressor, changed it and it all worked. Also had several where it was the pcb itself.

    Chris.