Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #51881
    jeremy
    Participant

    Hi

    Customer is reporting F3E fault code does anyone know what this code means?


    TIA

    Jeremy

    #309661
    washermanuk
    Participant

    Re: miele g7859

    Hi matey fault is Heating Level Switch defective! Does Not Switch On Heating level switch does not react to water pressure.
    Thick foaming cleaning or rinse agents in the waste water. This diminishes the waste-water pressure of the circulation pump at the heating level switch. . :rolls:
    all i could find hope it helps Brian

    #309662
    washermanuk
    Participant

    Re: miele g7859

    found more lol 😉
    After water intake, the heating level switch must switch. The query occurs 2 seconds over a length of 2 seconds in the following step. For target water measurements less than or equal to 1.1 gallons (4 liters) this fault monitoring is not active.
    Cause
    Heating level switch defective.
    Remedy
    Test the function of the circulation pump. See Service Mode 2, Description of Program Levels S21 to S24.
    Check the connection plugs and wires.
    Check the switch point of the heating level switch (2 seconds after circulation pump starts at nominal speed).
    Check the connection hose to the circulation pump for obstructions.

    #309663
    jeremy
    Participant

    Re: miele g7859

    Thank you
    😀