Miele T230C BLUE STAT BLOWING

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Miele T230C BLUE STAT BLOWING

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #52193
    trotter
    Participant

    I have just been out to one of these and replaced the “blue spot” stat above the heater, having cleaned a blocked condensor.

    A few hours later customer calls back…..no heat!

    I took the time to explain about air flow & not closing the door quickly mid cycle. I am guessing the stat has blown again.

    Is there a reason for this blowing other than air flow?

    Any comments appreciated 😀

    #310897
    pup
    Participant

    Re: Miele T230C BLUE STAT BLOWING

    got one doing same 😕

    #310898
    trotter
    Participant

    Re: Miele T230C BLUE STAT BLOWING

    Apparently……..some of the “blue spot” stats are of a higher temperature so it is important to order by model number – the higher temp stat has no blue spot I am told.

    Another cause is that the motor capacitor – it has been changed to 8mf I think. The problem was that the drum would stall mid cycle making the stat get too hot and go oc.

    Still have yet to solve mine though! going back tommorow & will report back 🙂