Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › AEG Super silent plus L76650 – NDA
- This topic has 9 replies, 3 voices, and was last updated 15 years, 11 months ago by
neon_3SP_glow.
-
AuthorPosts
-
April 21, 2010 at 4:52 pm #54111
neon_3SP_glow
ParticipantNo obvious defects on the 5 terminal motor. And no obvious defects on the Inverter board (impressive heat sink jobbie).
My instincts tell me it is the motor, I have not had much XP with these AEG super silent motors. Do they often go wrong, and is there an easy way to test if the windings are all as they should be?
The customer spent over (gasp!!) £600 on the product and it’s only 14ish months old.
April 21, 2010 at 5:07 pm #318440neon_3SP_glow
ParticipantRe: AEG Super silent plus 76650 – NDA
The induction three-phase motor mounted on EWM3000NEW, EWM25… and EWM35… appliances is powered by an “INVERTER” board, which has the function of converting the single-phase voltage to a three-phase
voltage.April 21, 2010 at 7:05 pm #318441bigchrisoioi
ParticipantRe: AEG Super silent plus L76650 – NDA
whats the fault?…whats the diagnostic code?……if you are working on this model, do not touch that invertor at least 30 mins after last use/test as that thing will discharge high voltage on you!!!!!!!…can you give us more info on what the fault/diagonstic code is???…..chris
April 21, 2010 at 9:12 pm #318442neon_3SP_glow
ParticipantRe: AEG Super silent plus L76650 – NDA
Hey, thanks for the advice there Chris. I was not aware of the danger. Luckily I didn’t get a shock.
Not sure how to access the diagnostics on this… Guessing now it is like any other Zannussi type.
No fault code has been shown as far as I am aware, but the motor refuses to turn. I will take another look this week and report any further findings/developments.
April 22, 2010 at 6:14 am #318443bigchrisoioi
ParticipantRe: AEG Super silent plus L76650 – NDA
no motor action is most likely that invertor board, costly little devils as well!!!!!good luck , and wear rubber gloves and use insulated pliers !!! lol
April 22, 2010 at 11:49 am #318444Martin
ParticipantRe: AEG Super silent plus L76650 – NDA
neon_3SP_glow wrote:I will take another look this week and report any further findings/developments.
The testing procedures on these beasts is rather different from their single phase cousins. If you would like some additional tech info then do please let me have your email details.
April 26, 2010 at 12:17 am #318445neon_3SP_glow
ParticipantRe: AEG Super silent plus L76650 – NDA
my e-mail address is…. gunner_3SP_frank@yahoo.com
that would be great Martin thanks.
April 26, 2010 at 7:40 am #318446Martin
ParticipantRe: AEG Super silent plus L76650 – NDA
It’s a 5mb pdf file on it’s way to you! (Hope you got room in your box?:D)
April 27, 2010 at 9:41 am #318447neon_3SP_glow
ParticipantRe: AEG Super silent plus L76650 – NDA
Martin wrote:It’s a 5mb pdf file on it’s way to you! (Hope you got room in your box?:D)
Many thanks Martin, I now have the pdf. Scheduled to re-call on wednesday, I will try to update the post with my findings! once again, many thanks.
September 7, 2010 at 10:33 am #318448neon_3SP_glow
ParticipantRe: AEG Super silent plus L76650 – NDA
srry for the late reply. The diagnostics said it was main PCB to blame, fitted new PCB on control panel and worked fine 😀
many thanks guys.
-