Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › hotpoint wdl520 nightmare!
- This topic has 10 replies, 5 voices, and was last updated 15 years, 10 months ago by
hilly.
-
AuthorPosts
-
June 2, 2010 at 5:16 pm #54965
hilly
Participanti replaced the drain pump on this model a few weeks ago, then got called back as it wouldnt dry so then replaced the heater and stat then a couple of days later got another call back! all the lights across the bottom flash rapidly and the spin and dry lights are on. if i turn it off at the wall then select a wash only cycle it goes for about a min, but the dryer heater heats up as its filling and washing? then the lights come on again?
ive had a module from emw with no joy & they have tested the display board for me, ive tried changing pressure switch & 3way valve with no joy,any ideas? paul
June 2, 2010 at 9:49 pm #321525billyblue
ParticipantRe: hotpoint wdl520 nightmare!
Is it the spiral heater? if it is i would consider trying another as they are prone to earth faults, also you must clean the condenser filter. Also check the one shot thermostat is not open circuit.
June 3, 2010 at 9:52 am #321526hilly
ParticipantRe: hotpoint wdl520 nightmare!
billyblue wrote:Is it the spiral heater? if it is i would consider trying another as they are prone to earth faults, also you must clean the condenser filter. Also check the one shot thermostat is not open circuit.
cheers, done all that. still scratching my head on this one!
June 3, 2010 at 5:27 pm #321527leavemetogetonwithit
ParticipantRe: hotpoint wdl520 nightmare!
That is one of the weirdest faults I have ever heard of. Time to call in the Penguin! Until he spots the thread, I’d advise trying disconnecting components one at a time and see what happens. Obviously, sometimes nothing will work with a component disconnected but you can get round that by substituting in another one. No need to actually change it, just lead / extend the wires out to a new component safely. You can do this with a heater element, pump, motor for example, without even needing to have an exact match. OK, the job’s going to be a loser, but you’ll surely learn something worth sharing with the rest of us.
Mike.June 3, 2010 at 8:08 pm #321528hilly
ParticipantRe: hotpoint wdl520 nightmare!
cheers for the replies
im picking the w/m up tomorrow so i can experiment in the workshop will let u know what happens, :bang:any info gratefully recieved 😉
June 13, 2010 at 7:24 pm #321529hilly
ParticipantRe: hotpoint wdl520 nightmare!
im still struggling with this one, i sent the module to emw for testing they have repaired it which has cured the problem with the heater coming on but it still shuts down and flashes after a few mins the only way ive been able to stop this is if i disconnect the thermistor plug (the one on the wash heater)??? ive nipped up the connections on module and thermistor and fitted a new thermistor and heater, also metered the wires, but no joy 😥
help pls :bang:
cheers paulJune 13, 2010 at 8:57 pm #321530helo_75
Participantis it the later heater box??? ie twith the thermistor at the front of the box? cos theyre a nightmare for failing, even during the wash
June 13, 2010 at 10:16 pm #321531hilly
Participanthelo_75 wrote:is it the later heater box??? ie twith the thermistor at the front of the box? cos theyre a nightmare for failing, even during the wash
no its the one with the spiral heater and theone shot inline cut out,
its the wash heater thermistor that seems to be the problem area?cheers paul
June 15, 2010 at 10:41 am #321532hilly
ParticipantRe: hotpoint wdl520 nightmare!
ive sent the module back to emw for testing, bloody hope they find a problem!!!
July 2, 2010 at 10:12 pm #321533hilly
ParticipantRe: hotpoint wdl520 nightmare!
just to let u know the conclusion of this saga to cure it i ended up replacing the module and the dryer thermistor! still cant work out the wash heater thermistor bit? but at least its going!!!
cheers for the replies, paul
June 9, 2011 at 12:12 pm #321534EVANO
ParticipantRe: hotpoint wdl520 nightmare!
Hi we’ve got a fault on one of these works fine in wash but 20 mins into dry stops code showing top two lights off spin and dry light on and bottom light off think it could be therminstor at front of box on new version heater box. Has anyone got the part number for this thermistor or is it the same as the other one.
many thanksLinda
-
AuthorPosts
- You must be logged in to reply to this topic.