    adv
    Participant

    no this is a beko. customer phoned sayin fuse had blown she changed it an blew again.no rcd on circuit old type fuse box. i go up have good look. around cant see anything bad. change fuse and away it goes. runs drains but no heat.getin power to heater.didnt have meter with me,and you all no aint got a megger. yet 😆 heater dont look badly damaged. and appliance only 2 year old.am thinkin heater but if thats the case would it take out the 13 amp fuse? help lads 😆

    #326400
    pup
    Participant

    Re: diplomat dw,hja8630

    well only to do is disconnect heater ? 😆

    #326401
    adv
    Participant

    Re: diplomat dw,hja8630

    but didnt think a heater would take out a 13 amp fuse.it doesnt look damaged atall ?

    #326402
    pup
    Participant

    Re: diplomat dw,hja8630

    then u need a megger , otherwise how u going to sort it? 😥

    #326403
    bigchrisoioi
    Participant

    Re: diplomat dw,hja8630

    not being rude, but how can you do the job without a megger????????

    should not every repair be tested?

    #326404
    pup
    Participant

    Re: diplomat dw,hja8630

    bigchrisoioi wrote:not being rude, but how can you do the job without a megger????????

    should not every repair be tested? well it will interesting to find out .may be he got pat tester ? 😆

    #326405
    adv
    Participant

    Re: diplomat dw,hja8630

    yep got pac 1000.info to helping fix the appliance would be more helpfull cheers 😆

    #326406
    keithwilliams
    Participant

    Re: diplomat dw,hja8630

    even a £2.99 multimeter would give you at least a continuity reading on the element. i have a seaward supernova plus pat tester. it’s the dogs b******* but it cant tell me if the elements open circuit unless its on heat cycle during a power-up test.
    like the guys say, get yourself a stand alone insulation tester and you’d have diagnosed the elements status straight away.
    finally of course it could take out a fuse. lets say that when it failed it went down to earth but since cooling off that earth fault has “healed” itself.
    oven elements do this all the time.

    #326407
    adv
    Participant

    Re: diplomat dw,hja8630

    cheers i have a meter mate.just was thinkin never had a dishwasher heater do this before, usualy just a dead short that takes out a 13 amp fuse.can you recomend a insulation tester thats not to pricey and will do the job cheers?

    #326408
    pup
    Participant

    Re: diplomat dw,hja8630

    well you have check motor ,mains filter ,ho let see pump wireing for shorting stats waterleaking, i think i cover most things 😆

    #326409
    adv
    Participant

    Re: diplomat dw,hja8630

    yeh had thing running for half hr with panels of. its must be heater ave told cus cheers

    #326410

    Re: diplomat dw,hja8630

    adv wrote:can you recomend a insulation tester thats not to pricey and will do the job cheers?

    Last time I looked there were plenty of excellent quality secondhand meggers on e-bay at very good prices. Heck, I sold my old one for a fiver on there when I got a more modern compact one. Was an analogue Eagle cost me £40 secondhand in 1988.
    Mike.