ise5-2 fault e10

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #56195
    petalpop
    Participant

    got a call monday for very irate customer
    cant find anything for fault e10
    would like to have some idea of what i am walking into please as someone else sold it but after one fault doesnt want to do the ig on it anymore so i get lumbered with it
    so any ideas please

    #326505
    kwatt
    Keymaster

    No communication with motor inverter or motor detected.

    Normally a loose plug or the inverter card faulty.

    HTH

    K.

    #326506
    petalpop
    Participant

    Re: ise5-2 fault e10

    ok cheers
    it has had a new pcb about 6 months or so ago
    so hopefully it is just a loose wire

    is a loose wire covered or is it chargable(load not correct so machine shook about) 😆

    #326507
    bazza500
    Participant

    Re: ise5-2 fault e10

    I have had a couple of these with a dry joint on the inverter board. A dod of solder fixed them.

    #326508
    petalpop
    Participant

    Re: ise5-2 fault e10

    cheers i will get it off and have a good look at it then

Viewing 5 posts - 1 through 5 (of 5 total)