Servis M2010 Tumble Dryer element confusion

Home Forums Public Support Forums Help And Support Washing Machine Help Forum Servis M2010 Tumble Dryer element confusion

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #56526
    KangarooPoo
    Participant

    Hi all, I have the Servis M2010 tumble dryer and the heating element is shot so I need to get a replacement. The problem however is that I seem to have some extra wires on mine that are not apparent in the pictures of the ones available online:

    Here’s the one I can get (from several places) online:

    Here’s the extra wires on my plug:

    Extra plugs at other end:

    Here’s where they go:

    Do I have to somehow remove the extra wires from the main plug and fit them to the new one? Is it easy?

    Thanks in advance for any help.

    Edit (After reading sticky! 😳 ): The model number is: 20012703145

    #327841
    Dales-Electronic
    Moderator

    Re: Servis M2010 Tumble Dryer element confusion

    Looking at this – three wires to heater (ie low heat, high heat and neutral) then the other two are to what would be the operating thermostat and over heat cut off stat (wired together in series) Looking at yours seems the stats are fitted to a seperate plate rather than clipped to the heater assy. I would just connect them up as is and see what you get.

    #327842
    KangarooPoo
    Participant

    Re: Servis M2010 Tumble Dryer element confusion

    Will give it a go, thanks for the advice.

    #327843
    KangarooPoo
    Participant

    Re: Servis M2010 Tumble Dryer element confusion

    Update: I’ve now wired in the new element and i’m still not getting any heat. I tried pressing the overheat cut-off reset button but it didn’t “click”, should it have? It just seems to slide in and out loosely.

    Any more ideas appreciated.

    #327844
    Dales-Electronic
    Moderator

    Re: Servis M2010 Tumble Dryer element confusion

    Have you got continuety through the thermostats ie through the two vacant tags.

    #327845
    KangarooPoo
    Participant

    Re: Servis M2010 Tumble Dryer element confusion

    The thermostats have been tested and are working but no, there is no continuity through the two vacant tags…. 😕

    Edit: I took the thermostats to an appliance shop and he tested them and said they were ok. However, i’ve just tested them myself and there is continuity through the cut out stat but not through the black heat stat.

    Does this mean I just need to replace the heat stat?