    Have a problem with this one, cleaned out condense pump a few weeks ago, found the usual lint and crap.

    Customer called back to say no water in drawer and electric tripped.
    Went back the other week and checked the pump, the pump ran o.k found water had been thrown onto element causing electric to trip.

    Could this pump be intermitantly faulty ❓

    Any help appreciated.

    John.

    #328798
    helo_75
    Participant

    no, its more likely the hole between the pump housing and the condenser is blocked… cured by poking something (like a tie wrap) through the hole,. bottom left hand side of the pump housing clearing the blockage

    #328799
    A1TEC
    Participant

    Re: Hotpoint CDT 00

    Thanks helo, will have a look at that.
    cheers

    John.

    #328800
    trotter
    Participant

    Re: Hotpoint CDT 00

    Had one doing the same a while back….fitted new pump & it cured the fault. Am I right in thinking there was a new design pump for this one?

    #328801
    Martin
    Participant

    Re: Hotpoint CDT 00

    trotter wrote:Had one doing the same a while back….fitted new pump & it cured the fault. Am I right in thinking there was a new design pump for this one?

    The early pump is now obsolete and replaced by pump kit (C00260640). On later models a new Float & pin kit where required and later still models have a shorter float to allow more water into the chamber. It is important therefore to note down the serial number of the machine in order to fit the correct combination of pump, float and in some cases water deflector too!

    #328802
    helo_75
    Participant

    its blocked!

    simple scenario.. if it wasnt blocked and the pump was faulty, the float would activate and the heater would switch off, light comes on, no more water cos of no heat.. quick repair

    blocked drain hole = no float switch activation, cos theres no water there, heater stays on, water condenses, builds up, pours into fan chamber and sprays on heater

    its common sense guys..

    #328803
    wilf
    Participant

    Re: Hotpoint CDT 00

    pump impellar is just a bit of rubber so you can hear the thing running but you have to look to see that its not physically broken. I was caught out on this just last week

    wilf

    ps I now keep the update pump kit only in stock and use only the pump if required the buying in price is the same pump only or kit

    #328804
    helo_75
    Participant

    like i said….

    EVEN IF THE PUMP IMPELLOR WAS BROKEN – IF THE DRAIN HOLE WAS CLEAR THE FLOAT WOULD SWITCH THE HEATER OFF

    shimples

    #328805
    A1TEC
    Participant

    Re: Hotpoint CDT 00

    It was a drain hole blockage, just as helo said. 😉


    cheers

    John.