Odd Miele condenser dryer fault

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Odd Miele condenser dryer fault

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #56867
    hodgheg
    Participant

    It’s a Miele T560C & during use the door solenoid operates (ie opens the door) fairly randomly but seemingly when the dryer gets to a high, though within range, temperature. Does it much less on the lower heat setting. Does anyone know if this is likely to be an electronic glitch or perhaps some sort of failsafe cutting in?

    Cheers, Richard.

    #329121
    chezza
    Participant

    Re: Odd Miele condenser dryer fault

    overheat stat tripping in…. could be restricted duct or inside blockage , or less likely stat failure

    #329122
    Seamy
    Participant

    Re: Odd Miele condenser dryer fault

    Yeah, door will open as a precaution if high temp is detected, most likely excess fluff has caused a blockage.