Zanussi ZWD 1472 S unusual washer dryer fault Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Zanussi ZWD 1472 S unusual washer dryer fault This topic has 4 replies, 3 voices, and was last updated 15 years, 6 months ago by Micky 32. Viewing 5 posts - 1 through 5 (of 5 total) Author Posts September 23, 2010 at 1:54 pm #57433 Micky 32Participant E20 and sometimes E10 when the dryer is running. Machine is draining ok. It runs ok without clothes. Any ideas? September 23, 2010 at 3:13 pm #331072 MadmacParticipant Re: Zanussi ZWD 1472 S unusual washer dryer fault Condenser ducting blocked, NTC wires broken at ducting and intermittent open circ valve coil are the usual suspects on recent ‘lux washer dryers Micky. September 23, 2010 at 8:11 pm #331073 bigchrisoioiParticipant Re: Zanussi ZWD 1472 S unusual washer dryer fault e10 > open circuit coil on valve e20 > blocked condensor September 24, 2010 at 11:24 am #331074 Micky 32Participant Re: Zanussi ZWD 1472 S unusual washer dryer fault Thanks for the info lads! Going back to it today and will post the outcome. September 25, 2010 at 11:48 am #331075 Micky 32Participant Re: Zanussi ZWD 1472 S unusual washer dryer fault Went back to machine. There was a lot of fluff in the condensor. Cleaned out and all is working again 😀 Author Posts Viewing 5 posts - 1 through 5 (of 5 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In