hotpoint wt960 f01

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #58212
    Davecas
    Participant

    door locks as soon as switched on at mains, will only unlock if mains switched off. When on/off on machine selected and program press start, pump impulses once then displays f01.

    I guess board fault? it has 3 phase motor (no brushes) motor meggers ok.
    anyone else had this fault?

    cheers

    #333749
    helo_75
    Participant

    f01 is a motor triac fault


    its always worth checking the wiring loom from pcb to motor, but quite often, its the pcb