    Help please freezer ices up in 2 days pushing back panel out is it gutter htr or defrost htr or defrost stat, or change em all

    #113994
    Dave_Conway
    Participant

    Re: HOTPOINT F/F MODEL FFO6W

    There’s three thermostats on the evaporator plus the two heaters so it’s a bit “overkill” to change all of them.

    One of the thermostats is the fan initiation one which should be open circuit in warm conditions, the other two will be nc, the two heaters can also be checked for continuity quite easily. It could also be the defrost timer.

    Part numbers as follows for all the parts:

    Timer 2600054
    Defrost heater 2600092
    Drip tray heater 2600061
    Defrost cut-out and thermal fuse (4 leads ?) 2600058
    Fan thermostat (2 leads) 2600059
    Thermal fuse (blue, 2 leads) 2600074

    Dave.

    #113995
    lotusray
    Participant

    Re: HOTPOINT F/F MODEL FFO6W

    freezing up in 2 days? seems a little quick if u are defrosting it propley
    i would check door is sealing correctly no damage to seal
    sounds like there is a lot of moisture entering freezer compartment