    Just left above machine with continual drain pump- spent hour on it covered everything and still totally flummexed-reading threads it appears putting it through dignostics and resetting could solve my brain ache.
    Is anyone in aposition to forward diagnostics info to me please?

    #334317
    BobHope
    Participant

    Re: zanussi zwf 14581 diagnostics

    insulation fault on the heater causes this, just disconnect the heater and see if it works, or better still do an insulation test with a decent insulation tester.

    Bob.

    #334318
    gandh1
    Participant

    Re: zanussi zwf 14581 diagnostics

    yes dont forget about the diagnostics!!!

    should be freely available if you have a connect account and pnc 🙂

    otherwise pm me your email…

    thing is constant drain is the machine in like a safelock mode, whyby almost anything electrical in it will cause this symptom :bang:

    once u have the diagnostics what you need to do is:

    read last error code first – (match up with error description, and check component(s) associated, replace if necessary)

    clear last error code

    run full diagnostic test routine.

    and so on…

    laborious but usually useful.

    #334319
    buzzard
    Participant

    Re: zanussi zwf 14581 diagnostics

    many thanks Bob & Ghand1 for responses- found info needed, eventually on mediator with connect.
    Going back on Friday- will hopefully post successful outcome then.

    #334320
    gandh1
    Participant

    Re: zanussi zwf 14581 diagnostics

    just be aware that there can often be more than one error code, so you might have to keep replacing and clearing error codes until the dignostic test run shows you E00 on position 10

    #334321
    buzzard
    Participant

    Re: zanussi zwf 14581 diagnostics

    Thanks v much. insulation on heater .4meg- disconnected and machine kicked into life.
    Didn.t show low reading other day as swung through from plug top- relays not energised then though!!! I feel they are overengineered appliances nowadays,bring back mechanical timers.
    New heater ordered- happy customer!!
    Cheers.