Hotpoint CTD40G condensing dryer completely dead

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hotpoint CTD40G condensing dryer completely dead

Viewing 9 posts - 1 through 9 (of 9 total)
  • Author
    Posts
  • #58503
    neilcook
    Participant

    All basic items checked. Low insulation reading of 1.25 m ohms?
    Door switch, float switch, circ pump, connections, heater etc all checked.

    On/off swtich dead as if no power to machine? Could it be main circuit board failure? Press switches appear ok on control panel can these play up?

    Thanks

    Neil

    #334728

    Re: Hotpoint CTD40G condensing dryer completely dead

    R.I.F. checked?
    Mike.

    #334729
    iadom
    Moderator

    Re: Hotpoint CTD40G condensing dryer completely dead

    One shot stat checked?

    Neutral is fed through the one shot on later machines, totally dead if this is O/C. 😉

    R.I.F. ❓

    #334730
    neilcook
    Participant

    Re: Hotpoint CTD40G condensing dryer completely dead

    Is the one shot stat the one above the door apeture just indside front panel? That was O/C when i checked it I’m sure?

    If it has gone, does that mean another problem with machine or could it be overloading?

    😛 RIF GOOD.

    Neil

    #334731
    iadom
    Moderator

    Re: Hotpoint CTD40G condensing dryer completely dead

    No, the one shot is near the heater, the doofer at the front is an NTC so may appear O/C on a simple continuity test.

    Testing the front NTC from the PCB connections should read 500kΩ at room temp.

    There have been several changes, full serial number would help to be certain.

    Jim.

    #334732
    neilcook
    Participant

    Re: Hotpoint CTD40G condensing dryer completely dead

    OK. Thanks for that. Will re-check.

    Many thanks

    Neil

    #334733
    neilcook
    Participant

    Re: Hotpoint CTD40G condensing dryer completely dead

    Serial Number is 802210180.
    CTD40G
    Mod number95313610000

    I notice there is a 3 part stat kit available?

    I’m sure she told me she had had it 18 months?

    Neil

    #334734
    iadom
    Moderator

    Re: Hotpoint CTD40G condensing dryer completely dead

    That does have the neutral wired through the one shot.

    The kit inlcudes three stats but you only need the NTC and one shot if it only has those fitted above the heater.

    The cycling stat was on originally, then taken off, then put back again. 😥

    Jim.

    #334735
    neilcook
    Participant

    Re: Hotpoint CTD40G condensing dryer completely dead

    Thanks, There are three stats above the heater on this machine.

    Neil

Viewing 9 posts - 1 through 9 (of 9 total)