Hotpoint BFI620 heater fault

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hotpoint BFI620 heater fault

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #59694
    Johnnyboy
    Participant

    Hi guys this one is 2+4 heater fault, the legs are broken (cemented in) and cant get the machine out, is there a way of checking heater continunity from the PCB? Im hoping its the PCB personally.
    Cheers Johnnyboy

    #339270
    iadom
    Moderator

    Re: Hotpoint BFI620 heater fault

    You would have to fill it to close the pressure switch then test between F2 on the PCB heater relay connection and the door switch.

    Or between F2 and one or other side of the detergent solenoid.

    Jim.

    #339271
    timdowning
    Participant

    Re: Hotpoint BFI620 heater fault

    If you can electrically disconnect the machine.

    Reach through the front right hand inspection panel and unplug the heater.

    Make a fly lead and test with that.