Electrolux ZNB4051 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Electrolux ZNB4051 This topic has 5 replies, 3 voices, and was last updated 15 years, 2 months ago by admin. Viewing 6 posts - 1 through 6 (of 6 total) Author Posts February 7, 2011 at 9:07 pm #60865 adminKeymaster i have a problem with a ZNB4051 925034408 (00 20061117) the fridge is not cold and the display is showing – instead of the temperature. any ideas please Thanks Simon February 14, 2011 at 8:12 pm #343932 adminKeymaster anyone got any ideas on this one please February 14, 2011 at 8:41 pm #343933 TheSpinDoctorParticipant Re: Electrolux ZNB4051 appleelectrics wrote:the fridge is not cold and the display is showing – instead of the temperature. Showing what mate? Anyway, usually either the evaporator is choked with frost (defrost heater o/c) of the fan can cut out intermittently (fan motor assy). February 24, 2011 at 3:24 pm #343934 adminKeymaster it just shows the line – February 24, 2011 at 9:32 pm #343935 martinmParticipant Re: Electrolux ZNB4051 the dash in display means the fridge temp is to low. check if evaporator is frozen up with frost all over then its probs heater or cut/outs. If its frozen with ice at rear the probs drain blocked March 3, 2011 at 9:22 pm #343936 TheSpinDoctorParticipant Re: Electrolux ZNB4051 Actually, the dash shows when the temp exceeds 9oC. Given it is too warm, that would be logical to show. Author Posts Viewing 6 posts - 1 through 6 (of 6 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In