March 1, 2011 at 1:18 pm #61380
Bernie
ParticipantHotpoint WT960 Dead
Fitted replacement board from EMW machine ok for 5days then got call back same fault sent board back to EMW no fault found with board power to machine, live & neutral to board.
Anyone know what else it might be going back to fit returned board on Wednesday 2nd
Thanks BernieMarch 1, 2011 at 10:04 pm #345898HotDog
ParticipantRe: Hotpoint WT960 Dead
console mod will prob gone get emw to test
March 1, 2011 at 10:53 pm #345899helo_75
Participantthere was a memo about this exact problem
check the pins in the plug to the fascia pcb
its not uncommon
March 1, 2011 at 11:08 pm #345900Bernie
ParticipantRe: Hotpoint WT960 Dead
Thanks for the quick reply
Bernie
March 2, 2011 at 8:42 am #345901Bernie
ParticipantRe: Hotpoint WT960 Dead
Was that all the memo said or was there more helo_75
Thanks BernieMarch 5, 2011 at 10:41 am #345902Bernie
ParticipantRe: Hotpoint WT960 Dead
Helo_75 Could you let me know if there was more in the memo as I am still having problems with this one?
I fitted the returned board checked the pins in the plug to the fascia and main pcb tested them for continuity all ok, put it on a spin to test worked for 3/4 mins cancelled program was going to put it on a wash when the front facia display started to flash then went blank machine dead. Sent both facia and main modules to EMW for testing, Tony could not find anything wrong.
Going back next week any help please.
BernieMarch 5, 2011 at 11:34 am #345903Martin
ParticipantRe: Hotpoint WT960 Dead
Being as Tony has tested both boards for you and that they worked OK initially until you cancelled the spin cycle. It does point toward there being a connection problem between the 2 boards.
It might be best to fit a new harness link between the two?(PartNo C00113957) 💡
March 5, 2011 at 11:44 am #345904Bernie
ParticipantRe: Hotpoint WT960 Dead
Thanks for that Martin, it’s the only thing I can think of trying too.
BernieMarch 8, 2011 at 11:15 pm #345905leavemetogetonwithit
ParticipantRe: Hotpoint WT960 Dead
What about a dodgy interference filter at the mains inlet?
Mike.March 9, 2011 at 11:39 am #345906Bernie
ParticipantRe: Hotpoint WT960 Dead
Thanks Mike will give that a look too, have orderd new Harness that goes between the two boards.
Bernie
March 9, 2011 at 1:17 pm #345907leavemetogetonwithit
ParticipantRe: Hotpoint WT960 Dead
Have just returned from looking at a WT960. Report was blew fuse, fuse replaced, completed wash. Subsequently blew trip, restored power, completed wash. Then blew trip again mid-wash, now totally dead.
Got there, meggered it, found heater down. Disconnected heater. Restored power. Display came up and would programme fine but as soon as start was pressed, display went out and everything dead again. (All took a bit longer than it sounds because of cramped space, short hose, dodgy lino etc.)
Did not remember this discussion, so did not look at fascia plug. Just told her to call Hotpoint (still doing £99 deal?) as I didn’t want all the faffing around with the fancy electronics and then have repair cost soaring anyway.
Now wondering if I did the right thing.
Mike. -