Hoover classica E1 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Hoover classica E1 This topic has 3 replies, 3 voices, and was last updated 15 years, 1 month ago by cornwell40. Viewing 4 posts - 1 through 4 (of 4 total) Author Posts March 4, 2011 at 10:33 am #61456 cornwell40Participant Can’t see these in the fault code guide (too old?) Customer getting E1 thought from memory it was a drain time out and sure enough the pump was cutting out. They called back today and its still the same. E1? Tony March 4, 2011 at 11:08 am #346250 helo_75Participant its a new wave and the heaters faulty March 4, 2011 at 1:47 pm #346251 timdowningParticipant Re: Hoover classica E1 Did you unblock the pressure chamber? Also shorten the pressure tube slightly. Oh and remove the eco ball. E1’s on the New Wave how I miss them!!! March 4, 2011 at 2:27 pm #346252 cornwell40Participant Re: Hoover classica E1 Helo wins the chocolate pig 😆 On both accounts 😳 Heater down to earth causing problems with the fill side. Tony Author Posts Viewing 4 posts - 1 through 4 (of 4 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In