Hotpoint TC71P Cond T/Dry – reversing timer?

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hotpoint TC71P Cond T/Dry – reversing timer?

Viewing 9 posts - 1 through 9 (of 9 total)
  • Author
    Posts
  • #61655
    MickGeorge
    Participant

    Hi folks

    Been to this today – no motor action/no heat.

    Suspect reversing timer as got supply from door stat to timer but nothing out to heater and wiring looks like it has all been overheating.

    I have only got wiring diagram for a TC11 so altho similar was difficult to test for motor action problem and can only assume there is an internal connection in the rev timer burnt out along with heater contact. Can hear the rev timer motor going tho?

    Anyone come across this before or got a wiring diagram so I can test properly?

    Whats involved with changing rev timer – looks a bit of a pig stuck under motor and fixing screw access looks a bit restricted to say the least.

    Help and suggestions appreaciated as allways

    Mick

    #347065
    iadom
    Moderator

    Re: Hotpoint TC71P Cond T/Dry – reversing timer?

    Have you disabled your e-mail address in your UCP ?

    I sent you a PM earlier regarding the Indesit dryer.

    And yes, this timer is a pig of a job to change. 😥

    Jim.

    #347066
    MickGeorge
    Participant

    Re: Hotpoint TC71P Cond T/Dry – reversing timer?

    Think I have returned your pm with my email address Jim

    Thanks

    Mick

    #347067
    iadom
    Moderator

    Re: Hotpoint TC71P Cond T/Dry – reversing timer?

    Not received anything yet, also my PM to you does not appear in my PM folders????

    Sent you another which does appear to have got through.

    Jim.

    #347068
    MickGeorge
    Participant

    Re: Hotpoint TC71P Cond T/Dry – reversing timer?

    Just replied to your new PM so hopfully you got this one 🙂

    Thanks

    Mick

    #347069
    iadom
    Moderator

    Re: Hotpoint TC71P Cond T/Dry – reversing timer?

    Eventually. 😥

    Its taken me over 20 minutes to get this thread to load.

    The TC11 tech info is exactly the same for the TC71.

    Will sort out the Indesit stuff for you.

    Jim.

    #347070
    MickGeorge
    Participant

    Re: Hotpoint TC71P Cond T/Dry – reversing timer?

    Many thanks for the email Jim re the Indesit m/c

    Hmmm.. I am sure the TC11 wiring diagram showed 4 motor conections going to the rev timer and I only found 3 + wiring colours were different as well – think I will have to re-check.

    Any tips for changing the reversing timer on these anyone?

    Thanks

    Mick

    #347071
    iadom
    Moderator

    Re: Hotpoint TC71P Cond T/Dry – reversing timer?

    I used an angled screwdriver, moles grips, pliers anything I could to get the darned screws out.

    #347072
    MickGeorge
    Participant

    Re: Hotpoint TC71P Cond T/Dry – reversing timer?

    Sorry guys meant to finish this off.

    Was definatly the rev. timer – over heated wiring must have melted or disloged the timer gearing as the time motor was running but not opperating either the motor or heater contacts.

    Found the TC71 wiring diagram was a supliment to the TC11 manual and must have fell out as i found it after your comments Jim.

    Managed to get the timer out after removing capacitor to make life easier and used a small rachet with a posidive bit to realase screws – far screw was in a slotted hole so didn’t have to uscrew all the way out but found the nearside screw a pain to get started so had to thread hole with screw first before trying to refit which helped.

    Thanks for all the help Jim

    Mick

Viewing 9 posts - 1 through 9 (of 9 total)