Whirlpool 3RLEQ8033sw1

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #61848
    geoff1
    Participant

    Hi

    ❓ Can anyone advise why the duct stat with red dot does not even last a load before it goes o/c? (480112100395)
    I have cleaned all the pipes to ensure that they are not blocked or resticted.
    Just in case I have missed something

    many thanks

    Geoff

    #347853
    electrofix
    Moderator

    Re: Whirlpool 3RLEQ8033sw1

    this dryer works on vacuum

    the motor causes a vacuum in the drum which pulls the air in over the element

    so you are lookin for

    1 air flow problems which includes recirculation of the hot air

    2 leaks in the drum seals if these seals leak cold air gets in but more important the air is bypassing the element causing it to overheat

    hope this helps

    Dave

    #347854
    electrofix
    Moderator

    Re: Whirlpool 3RLEQ8033sw1

    ps you can reset stats by tapping them on the floor firmly

    Dave

    #347855
    EFS
    Participant

    Re: Whirlpool 3RLEQ8033sw1

    electrofix wrote:ps you can reset stats by tapping them on the floor firmly

    Dave

    Works even better if you put it in a freezer first

    Steve

    #347856
    geoff1
    Participant

    Re: Whirlpool 3RLEQ8033sw1

    Thank you very much for replies.

    Will go over the seals etc to see what is happening.

    Thank you for your tips on resetting these stats 😀

    Geoff

Viewing 5 posts - 1 through 5 (of 5 total)