tricty bendix dh 104w tripping rcd

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries tricty bendix dh 104w tripping rcd

Viewing 10 posts - 1 through 10 (of 10 total)
  • Author
    Posts
  • #62586
    slyp98
    Participant

    hi all , having a bit o trouble with this customer sayes its tripping main rcd 60a and not the socket rcd , it starts ok then after a few minutes trips the rcd . the door switch doesnt work i dont think that has anything to do with the problem circ motor working ok and pump also working no sign of water anywhere and the element is reading 26.5 ohms anyone have any info on these models thanks

    #350554
    BobHope
    Participant

    Re: tricty bendix dh 104w tripping rcd

    does the door latch close the door correctly if not it will be water ingress into the door lock assembly.

    11 digit PNC code required if you need parts or info

    Bob

    #350555
    slyp98
    Participant

    Re: tricty bendix dh 104w tripping rcd

    cheers bob pnc is 911911018/02

    #350556
    BobHope
    Participant

    Re: tricty bendix dh 104w tripping rcd

    pm me your email and i will send some info.

    Bob.

    EMAIL sent.

    #350557
    slyp98
    Participant

    Re: tricty bendix dh 104w tripping rcd

    i had a look last night yeah the door is closing fine bob i’m trying to pinpoint at what stage the rcd trips , it takes in water does a quick rinse and then trips . if you move the timer on a bit it starts up again (after resetting the rcd) which leads me to believe its a component , maybe stat or a solenoid or the timer itself

    #350558
    slyp98
    Participant

    Re: tricty bendix dh 104w tripping rcd

    more sinister problems , i need a wiring diagram , is there any test procedures for these models ? the door switch when operated trips the rcd ! it will work ok with the switch removed from the door until a certain point in the cycle and then trip also , ive checked everything door wiring , motor , pump element, solenoids ,stat

    #350559
    BobHope
    Participant

    Re: tricty bendix dh 104w tripping rcd

    pm me ou email address and i will forward some info.

    Bob.

    Emails sent.

    #350560
    slyp98
    Participant

    Re: tricty bendix dh 104w tripping rcd

    hi again bob no sign of a wiring diagram , anyone else got one thanks

    #350561
    Martin
    Participant

    Re: tricty bendix dh 104w tripping rcd

    slyp98 wrote:anyone else got one thanks

    Let me have your email and I’ll send you a copy…. 😀

    #350562
    slyp98
    Participant

    Re: tricty bendix dh 104w tripping rcd

    ok solved this baby , pipe from heater element on outside r/h side to the top spray arm , water leak a trickle down outside of tub hitting motor , element etc

Viewing 10 posts - 1 through 10 (of 10 total)