  • #62717
    robbo1973
    Participant

    customer complaining of freezing at bottom of fridge which it is ,I ran the self test and the fridge baffle opens and closes fine but the fridge sensor reads 9 degrees so it looks like it is reading wrong.
    Has anyone had this before?

    cheers chris

    #351063
    admin
    Keymaster

    Re: beko AP930X

    Hi

    Is the freezer fan running correctly?

    Also are the drawers in the correct position as some models have a drawer that allows air direct to the drawer compartment and if its out of position it will cause freezing of the base of the fridge.

    Also there is normally a channel that ducts the air from the top air inlet down to the bottom and the vent could be either worn or allowing airto go through.

    Bryan

    #351064
    franz
    Participant

    Re: beko AP930X

    Hi Chris could you send me any tech info such as self test procedure & fault codes if you have it as I am having probs with one as well .
    Thanks Franz

    #351065
    Seamy
    Participant

    Re: beko AP930X

    Fan seizing up in freezer.