Electrolux ER78311 stat problem?

Home Forums Public Support Forums Help And Support Fridge And Freezer Forum Electrolux ER78311 stat problem?

Viewing 12 posts - 1 through 12 (of 12 total)
  • Author
    Posts
  • #63251
    Sproz
    Participant

    Hi,
    I think I have a faulty stat on my built in fridge freezer but need some clarification first!
    The compressor is running all the time unless I turn the stat off
    The stat knob does not make a clicking noise as you turn it telling me it thinks its not reached temp.
    The fridge is building up with ice and the food is very cold but not frozen
    The freezer is very very cold, my youngest cannot soft scoop his ice cream!!
    Door seals seem ok
    Fault appeared after the last defrost I think, after I turned the stat off.

    Do you think I’m on the right track?
    How much for a new one?
    Whats the procedure for fitting the new stat, does the fridge have to come out?

    Thanks in advance!

    #353089
    kwatt
    Keymaster

    Re: Electrolux ER78311 stat problem?

    Yes, almost certainly the thermostat.

    Can you clarify the model number though as there’s not a thing for that model number coming up?

    There’s a ER7831I but there are several versions of it depending on the PNC code, which you can get off the rating plate. There’s different stats depending on the PNC and serial number so both are needed to pinpoint the one you need.

    HTH

    K.

    #353090
    Sproz
    Participant

    Re: Electrolux ER78311 stat problem?

    Hi,
    The product code is 925-694-601
    Electrolux list a few different datecodes for this model, I cannot see a datecode but seem to remember it was around 2000-2001

    #353091
    Sproz
    Participant

    Re: Electrolux ER78311 stat problem?

    oops..forgot the serial#
    serial; 11600331

    #353092
    kwatt
    Keymaster

    Re: Electrolux ER78311 stat problem?

    From the info it should be, 2262324045 listed here.

    HTH

    K.

    #353093
    Sproz
    Participant

    Re: Electrolux ER78311 stat problem?

    Hi Thanks for that,
    How easy is the replacement?, does the fridge/freezer have to be removed from the kitchen cabinet?
    ta

    #353094
    washtronics
    Participant

    Re: Electrolux ER78311 stat problem?

    i have changed one on an AEG freezer, (same company) yes the freezer has to come out from the housing unit and the capillary from the stat is outside the cabinet and goes through a small hole usually sealed with a blue tac type seal

    #353095
    Sproz
    Participant

    Re: Electrolux ER78311 stat problem?

    Things are never easy!!

    #353096
    Sproz
    Participant

    Re: Electrolux ER78311 stat problem?

    Hi…Ok stat replaced yesterday but noticed a problem… The compressor has recently been running continuosly because of the broken stat with the fridge evap having a layer of frost on it, when I changed the stat yesterday I noticed the fridge was a little warm with no frost, today the milk is off etc and the comp is still running all the time. Freezer chilled down as quick as normal after the defrost and is fine this morning.
    Its making all the usual gurgling sounds but i wonder if having the comp running for many weeks all the time with the broken stat has done something else???? I’m thinking it looks like its short of gas??? Can domestic fridges be re-gassed?
    Help!!
    Please!

    #353097
    washtronics
    Participant

    Re: Electrolux ER78311 stat problem?

    they can be regassed but usually they have lost gas for a reason so if it is regassed and only lasts a short time then it is time to replace the fridge

    #353098
    Sproz
    Participant

    Re: Electrolux ER78311 stat problem?

    As the day has got on I’ve noticed a build up of ice up the bottom right hand side of the fridge, probably where the pipe goes up, but only condensation around the top part where i guess the evaporator is, checked the door seals and they seem fine but the fridge is still warm?
    There’s lots of hot air coming off the condensor, which tells me its pulling heat out of somewhere!

    #353099
    Sproz
    Participant

    Re: Electrolux ER78311 stat problem?

    this is strange… The top part of the back of the fridge is frosty but the fridge still feels a little warm, i would guess that the door seals have gone but I’ve checked all around and they are fine?
    Any ideas???

Viewing 12 posts - 1 through 12 (of 12 total)
  • You must be logged in to reply to this topic.