  • #63776
    JamoAus
    Participant

    Hey guys, I’m Glenn from australia, nice to meet ya =)
    Somebody on another forum recommended I try asking here..

    I have a Fisher and Paykel “intuitive eco” washing machine model IW810AU , and when switch is off, (power point on) drain pump is buzzing. It measures 36 Ohms and works on the bench when removed.
    It doesn’t work on diagnostic mode using the fabric care button and no fault code comes up.

    Any ideas apart from replacing the motor controller?
    Regards
    Glenn

    #354876
    ratbag_359
    Participant

    Re: IW810AU pump buzzing

    So the machine can’t operate it?
    And you can turn on the machine and will fill, wash,etc?
    Just won’t drain?
    If that is the case the triac in the motor controller has failed. or the control circuit for the triac has.

    #354877
    JamoAus
    Participant

    Re: IW810AU pump buzzing

    Hi there,
    Yes it does fill and wash, but not drain. During this drain motor continues to buzz. Occasionally the machine will cut out completely and needs a minute or two to reset.
    Foud my house voltage to be 253v but when I connect it to my generator (241v) it works fine.
    Regards
    Glenn

    #354878
    ratbag_359
    Participant

    Re: IW810AU pump buzzing

    That is a interesting issue do live in town or out in the country?

    #354879
    JamoAus
    Participant

    Re: IW810AU pump buzzing

    Hi again,
    It is a teaser. I live 16KM out of town, sort of semi rural. Neighbour has the same voltage @ 253 V.
    Regards
    Glenn

    #354880
    ratbag_359
    Participant

    Re: IW810AU pump buzzing

    well the voltage is within limits.
    But the motor should still run.
    The only thing apart from the machine having a quirky fault is the supply for the house been bad like a bad neutral.

    #354881
    JamoAus
    Participant

    Re: IW810AU pump buzzing

    Hi there,
    Dropped the voltage to 249 by plugging in a 800 watt heater and machine worked perfectly. Have to ring my supplier to find out why it is high. Thanks for your help.
    Regards
    Glenn

    #354882
    Allsorts
    Participant

    Re: IW810AU pump buzzing

    Re the Voltage.. proberbly just means low demand on the supply

    #354883
    ratbag_359
    Participant

    Re: IW810AU pump buzzing

    There maybe a bad neutral on the transformer feeding your house.
    Or the power in your area may need conditioning.

    Allsorts wrote:Re the Voltage.. proberbly just means low demand on the supply

    Agreed. Also bad neutral can cause it too. A few years ago in a rural area a lug for the neutral burned right off two houses ended up with 500volts coming in 😯

Viewing 9 posts - 1 through 9 (of 9 total)