Thanks for that always useful if you’ve never worked on one before.
Turned out to be a condenser problem. Although customer said they had cleaned the unit they hadn’t done it properly.
I.e. you could see through the condenser side ways but it was blocked looking length ways. At least they know now.
A clue was a lot of excess water in the condenser and chamber.
I also removed the pump to see weather it was blocked. Bit of job, you have to take the back panel off. Not as easy to access as the Hotpoint variants.
Hope this helps anyone who’s not seen one before.