Haier Washer/Dryer

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #63812
    TonyMower
    Participant

    Haier W/D (i know its a hoover)
    Mod. HJA8703
    Prod/S.N. 08133578/31800058

    Ok, went to customers house for ‘no spin’. Found no motor action at all, so went straight to the motor/module to have a look. Found module blown due to motor loom chaffed through onto the module heatsink. Customer wanted new board so i ordered and replaced it(also repaired chaffed wire). Proceeded to test appliance and seemed to work ok, motor running nicely. Re-installed and tested again to be sure, filled, motor started, heater kicked in and looked ok….after about 2 minutes(once heater turned on) the machine stopped and i got 11 flashes (Dryer board/wiring faulty). Re-checked wiring, looks ok and resistance readings all ok, no earth leakage etc. Any ideas or has anyone come across this problem before?
    Thanks

    #355051
    BobHope
    Participant

    Re: Haier Washer/Dryer

    E11 is a well know problm with the dryer NTC and wiring to it.
    technical notes have been issued for this fault, you need to replace the dryer ntc and wiring to it.

    email addres and i will send you some info.

    Bob.

    #355052
    TonyMower
    Participant

    Re: Haier Washer/Dryer

    Hi Bob can you send me the details for this error? Many Thanks for your help.
    PS do you have the part numbers?
    tony@arrowdene.co.uk