    simllfixit
    Participant

    Hi, can any body help me with this one? the light stays on after filter has been cleaned and replaced. would be very greatfull of any assistance as im going to go and look at it soon.

    thanks Simeon.

    #117427
    BobHope
    Participant

    Re: candy cic60 clean filter light on.

    Is the appliance still working ok ?

    i bet it has no heat due to the microtemp fuse in the heater being O/C.

    Cheers Bob

    #117428
    simllfixit
    Participant

    Re: candy cic60 clean filter light on.

    thanks for your reply, i will have to find out tomorrow as im only going from an answerfone message i was left. cheers Simeon

    #117429
    Cleat
    Participant

    Re: candy cic60 clean filter light on.

    Most certainly is microtemp fuse.. we have done 3 in as many weeks.. think its 152oC but will check…

    #117430
    Dave_Conway
    Participant

    Re: candy cic60 clean filter light on.

    Yep, definite the thermal fuse o/c.

    Cleat will supply the correct temperature replacement hopefully, I can’t recall what it is either 😕

    Dave.

    #117431
    steve57
    Participant

    Re: candy cic60 clean filter light on.

    hi
    repaired one today put in a new the thermal fuse ,fault cured,

    regards
    steve

    #117432
    Cleat
    Participant

    Re: candy cic60 clean filter light on.

    Yeah my memory did serve me correctly.. it is 152oC ….

    #117433
    Cleat
    Participant

    Re: candy cic60 clean filter light on.

    We have another doing same…lol.. But keeps re-blowing thermal fuse after about 5mins,, so gonna try the Blue spot TOC inside the element… but connections show only a complete Element… Any one know part number for blue spot stat ?… Thanks..

    #117434
    Martin
    Participant

    Re: candy cic60 clean filter light on.

    Cleat wrote:keeps re-blowing thermal fuse after about 5mins

    Sorry Cleat no idea of the value of the TOC on the element itself 🙁

    But HOLD UP for a minute, you say it keeps blowing the Microtemp ❓ Then it must be getting bl**dy hot around there ❗ Have you checked the fan chamber, condensor and ducting is giving good air flow to the element in the first place ❓

    I would suspect an air flow problem you got there mate 🙂

    Martin

    #117435
    Cleat
    Participant

    Re: candy cic60 clean filter light on.

    All airways clean and free 😥 ….. Toc was cheaper option than element complete.. toc maybe not cutting out.. just blowing thermal cutout ?? 💡