    hi everyone does anyone know a way to test the reed switch on the water inlet pcb other than replacing it,or is there a way of by passing it to test if it is at fault.the inlet/drain light flashes as soon as the machine takes in water but it carries on filling and then nothing.any help much appreciated.

    #355890
    electrofix
    Moderator

    Re: miele g975 sc plus reed valve

    you cant bypass it because it needs to pulse to send a signal to the pcb
    you can test reed switches with a multimeter and a magnet

    only way you could bypass it is to solder 2 wires to a push switch and when machine start you push the switch on and off fast as you can, but reed has got to have failed o/c for this to work without removing it

    Dave

    #355891
    JENKS
    Participant

    Re: miele g975 sc plus reed valve

    thanks for reply,do you know if these reed switches are normally open or normally closed when machine off

    #355892
    electrofix
    Moderator

    Re: miele g975 sc plus reed valve

    depends where the magnet stops

    reed switches are activated by magnets so if the magnet stops next to it then switch will be closed

    Dave

    #355893
    JENKS
    Participant

    Re: miele g975 sc plus reed valve

    doesnt seem to be a magnet anywhere near.the switch is on a small pcb which slots into compartment on the water matrix.

    #355894
    eastlmark
    Moderator

    Re: miele g975 sc plus reed valve

    the magnet will be on the wheel inside the air break.

    #355895
    JENKS
    Participant

    Re: miele g975 sc plus reed valve

    is it possible to access the magnet,i ve been told these can come loose.