john lewis jlwm1201 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › john lewis jlwm1201 This topic has 5 replies, 3 voices, and was last updated 14 years, 7 months ago by adv. Viewing 6 posts - 1 through 6 (of 6 total) Author Posts August 31, 2011 at 12:45 pm #64773 advParticipant this comin up with e 50 help lads any ideas machine wont do anything? August 31, 2011 at 1:03 pm #358029 CriscoldParticipant Re: john lewis jlwm1201 E51 Motor power supply triac short-circuited PCB faulty; current leakage from motor or from wiring. E52 No signal from motor tachometric generator Motor faulty; wiring faulty; PCB faulty E53 Motor triac sensing circuit faulty PCB faulty E54 Motor relay contacts sticking PCB faulty; current leakage from motor or from wiring You need to enter diagnostics to find the correct error code Colin August 31, 2011 at 1:13 pm #358030 electrofixModerator Re: john lewis jlwm1201 had done the same info criscold beat me to it check for motor shorts to earth that can cause E51 faults check obvious like brushes if motor turns and stops check for tacho output Dave August 31, 2011 at 1:40 pm #358031 advParticipant Re: john lewis jlwm1201 when i held reset an another button all lights flash up and down as i moved timer knob round e51 came up is that the pcb duff en? ta September 1, 2011 at 8:14 am #358032 electrofixModerator Re: john lewis jlwm1201 same fault code comes up if motor has an earth fault ie wet or carbon dust Dave September 1, 2011 at 8:59 am #358033 advParticipant Re: john lewis jlwm1201 cheers lads Author Posts Viewing 6 posts - 1 through 6 (of 6 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In