  • #65144
    stevie w1
    Participant

    machine wont dispence water , i close the door select settings from controller press start ,door lock comes on but water dose not go into soap dispenser i have check mains water supply all ok

    #359260
    iadom
    Moderator

    Re: hoover nextra hnl 662 80

    Will the machine drain and spin?

    #359261
    stevie w1
    Participant

    Re: hoover nextra hnl 662 80

    starts a spin cycle then stops about one min. starts as if it is going to a full spin then stops door lock still on setting is 15 on front of machine does not seem to drain

    #359262
    iadom
    Moderator

    Re: hoover nextra hnl 662 80

    Could be a faulty drain pump, quite common to get leaks onto the pump, can often lead to failure of the main PCB. 🙁

    #359263
    seagull
    Participant

    Re: hoover nextra hnl 662 80

    stevie w1 wrote:starts a spin cycle then stops about one min. starts as if it is going to a full spin then stops door lock still on setting is 15 on front of machine does not seem to drain

    open circuit drain pump most likely

    #359264
    stevie w1
    Participant

    Re: hoover nextra hnl 662 80

    do you get cotinuity across the two spades of the drain pump

    #359265
    iadom
    Moderator

    Re: hoover nextra hnl 662 80

    It depends on what you are testing it with but resistance should be around 160? to 180?.

    #359266
    stevie w1
    Participant

    Re: hoover nextra hnl 662 80

    tested with a fluke. pump goost . will order one cheers ,thanks for all the info hoover engineer wanted 169 pounds as my warrenty had just run out Being and old miserable heating engineer didnt want to part with that amoumt of money ..cheers

    #359267
    iadom
    Moderator

    Re: hoover nextra hnl 662 80

    If you are lucky it will just be a faulty pump. Look closely for any signs of water ingress. It shouldn’t really be happening so soon but the inlet hose from the dispenser to the drum can leak where it slots into the outer drum.

    You should also make sure the replacement pump has an internal TOC, some don’t and if the pump gets jammed they will often take out the main pcb if there is no overload protection.

    #359268
    stevie w1
    Participant

    Re: hoover nextra hnl 662 80

    wasnt lucky, got new pump ,fitted still no water at solnoids ,but drum would now spin. had to buy PCB. cheapest was candy/hoover to my suprise .PCB fitted machine working like a goodning still hate hoover thanks again for the advice iadom and seagull

    #359269
    iadom
    Moderator

    Re: hoover nextra hnl 662 80

    stevie w1 wrote: still hate hoover

    Perhaps you should direct your ire at Candy, thats what your machine is after all. :rolls:

Viewing 11 posts - 1 through 11 (of 11 total)