  • #66168
    adv
    Participant

    power goin into this but wont start programmer doesnt light up. thinkin pcb advice lads ta

    #363330
    A1engineer
    Participant

    Re: hotpoint dw model lft114

    have a look for broken wires in door, take of door skin there is a thin bar running across inner door, behind that you will find 1 or more broken wires, could possibly have caused board fault but might just be wires.

    Kev

    #363331
    adv
    Participant

    Re: hotpoint dw model lft114

    hi mate didnt think the new type dw get broken wires these days as the wires dont usualy go were the door goes up and down ust to be very common on older models?

    #363332
    iadom
    Moderator

    Re: hotpoint dw model lft114

    This is an Indesit machine we are talking about, as Kev says, some of the wires in the door harness are very thin and break off under the rod going across the centre of the door.

    There isn’t a standard dishwasher on the market were the wires don’t go up and down at some point. It would be very common on these but not many of them get to be ‘older models’ :rolls:

    #363333
    adv
    Participant

    Re: hotpoint dw model lft114

    ok lads al have closer look ta

    #363334
    adv
    Participant

    Re: hotpoint dw model lft114

    you no what a meen tho the new ones are usualy in a plastic cover , not like the old phillips and candy wrapped in tape am peace of rubber sheath ahh the good old days. crimping all they wires with a harness kit lol

    #363335
    johnnyj
    Participant

    Re: hotpoint dw model lft114

    Had a few of the console boards causing this and as the guys say the wiring getting stuck in the insulation and breaking also.

    #363336
    adv
    Participant

    Re: hotpoint dw model lft114

    ta

    #363337
    iadom
    Moderator

    Re: hotpoint dw model lft114

    Did one yesterday, there are only a few wires in the door harness, a couple of normal thickness ones and six or seven of the feeble thin ones.

    On this one both of the thick wires had snapped at the bottom. :rolls:

    Jim.

    #363338
    A1engineer
    Participant

    hotpoint dw model lft114

    adv wrote:hi mate didnt think the new type dw get broken wires these days as the wires dont usualy go were the door goes up and down ust to be very common on older models?


    Sadly these are ineshit, been to loads of ” new” dw under warranty needing wiring repaired.

    This is very common and will no doubt get worse as they get older..

    On the flip side its a nice eay job for us. 🙂

    Most common complaint is ” not starting or dead” usually 1 or both of door lock wires snapped.

    #363339
    adv
    Participant

    Re: hotpoint dw model lft114

    thanks for reply

    #363340
    keithwilliams
    Participant

    Re: hotpoint dw model lft114

    ive had this as well. unfortunately after spending ages soldering and heatshrinking a repair to about four wires i discovered that they must have shorted and blown the board.therefore id quickly splice and test then solder if ok.

    #363341
    adv
    Participant

    Re: hotpoint dw model lft114

    hi lads this dw a had a look at wires none broken . but started working again a moved harness up a bit , how the hell do you get to the pcb anyway at bottom.?took the 2 srews out of panel at bottom front but couldnt get the plastic cover off ? or does it come off help lads?

    #363342
    iadom
    Moderator

    Re: hotpoint dw model lft114

    That still sounds like a harness fault, you need to remove all of the black tape covering the harness where it bends at the bottom, had several now with breaks there.

    Cover prises off, with care of course. 😉

    #363343
    adv
    Participant

    Re: hotpoint dw model lft114

    Ok what a pig ti get of joke