    When on dry cycle F13 shows then machine stops.Heater element and thermistor check ok as does water inlet valve.
    Does F13 suggest a water inlet fault??

    #365210
    iadom
    Moderator

    Re: Hotpoint Aqualtis AQM8F49I Washer Dryer F13

    F13 = Dryer NTC open or short circuit.

    Check efficiency of contacts on connector J011 (commutator motor fitted) or
    J14 (three-phase) on PCB;
    – Check NTC impedance value on wiring connectors J011
    (commutator) or J14 (three-phase) between pin 1 and pin 2.
    The impedance value at ambient temperature (20°C) must be
    approximately 20 KOhm;
    – If measurement is incorrect check NTC wiring;
    – Check the same parameter directly on the NTC (20 KOhm);
    – Renew NTC;
    – Renew PCB.

    #365211
    johnnyj
    Participant

    Re: Hotpoint Aqualtis AQM8F49I Washer Dryer F13

    The dryer thermistor on these is the same as the wash thermistor, and it causes some funny faults F13 you also get them not pumping change the thermistor and its cured, i’d try a new one and also check the harness where it clips to the cabinet the thin wires sometimes break causing intermitant F13 faults.