neff S4453n0gb/13 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › neff S4453n0gb/13 This topic has 5 replies, 4 voices, and was last updated 14 years, 3 months ago by clockworkone. Viewing 6 posts - 1 through 6 (of 6 total) Author Posts December 20, 2011 at 2:03 pm #66982 clockworkoneParticipant what kind of a job is it to fit heater(491755) on this one.not seen it yet but fault reported is m/c wont stop until you switch it off. December 20, 2011 at 3:28 pm #365817 spimpsParticipant Re: neff S4453n0gb/13 Busy 90 minutes or so depending on if its built in,wash chamber has to be split from the plastis base,not the easiest but OK to do. December 20, 2011 at 6:05 pm #365818 clockworkoneParticipant Re: neff S4453n0gb/13 many thanks for reply.paul December 20, 2011 at 6:43 pm #365819 leavemetogetonwithitParticipant Re: neff S4453n0gb/13 Read Martin’s opening post in, “Tips, Tricks and Shortcuts.” Mike. December 21, 2011 at 4:30 pm #365820 spimpsParticipant Re: neff S4453n0gb/13 Doesn’t get any better than Martins post,spot on. December 21, 2011 at 7:24 pm #365821 nomadPaulParticipant Re: neff S4453n0gb/13 A faulty / open circuit heater is NOT the most common cause of no heating…..low water levels are . Check the pressure chamber/fill hose first . Author Posts Viewing 6 posts - 1 through 6 (of 6 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In