ParticipantMachine starts on wash prog..drains, then when water should be taken,aborts and ends.Water supply and valves ok.Seems to be a control fault? E30 flashes up occasionaly.
March 12, 2012 at 4:48 pm #370858Martin
ParticipantRe: Zanussi ZWF1431W Washing machine E30
Heater element up the swannie……..
March 15, 2012 at 6:28 pm #370859Latham63
ParticipantRe: Zanussi ZWF1431W Washing machine E30
Martin,tried a new heater(old one tested ok with mega),initially started to work,taking in water!Tested this twice,ok. Then when I thought all was well,started up again, prog aborted and E30 again! All I can think is module fault?
March 15, 2012 at 6:44 pm #370860Criscold
ParticipantRe: Zanussi ZWF1431W Washing machine E30
Have you tried diagnostics ? could be pressure switch or airtrap fault
March 16, 2012 at 8:09 am #370861Latham63
ParticipantRe: Zanussi ZWF1431W Washing machine E30
Not sure how to do diagnostics on this machine? Never heard of air trap?
March 16, 2012 at 8:28 am #370862Criscold
ParticipantRe: Zanussi ZWF1431W Washing machine E30
I think this should help – I think page 16 onwards for this model
Colin
March 22, 2012 at 10:45 pm #370863Latham63
ParticipantRe: Zanussi ZWF1431W Washing machine E30
Thanks for diagnostic info.Have since taken machine to my workshop,plugged in and it works perfectly!!
Now suspect the customers house electrical supply fault!March 23, 2012 at 12:05 pm #370864leavemetogetonwithit
ParticipantRe: Zanussi ZWF1431W Washing machine E30
Latham63 wrote:Never heard of air trap?
The pdf Chris posted between p27-p28 gives the E3* series of codes. Mostly p/sw related. So you may have a colourcatcher or suchlike causing an intermittent blockage around the pressure vessel (= air trap?) which IIRC is integral with the sump hose.
If you haven’t already done so, take a good look in that sump hose, especially around the eco-ball. Analogic p/sws have also been known to give trouble.
Incidentally, when you changed the element and it worked a couple of times, that might have been due to you disturbing the blockage.
Mike. -