Re: Hotpoint F/L/A (WMF560) – F06 error
In the manual it also states F06 as N/A in the quick reference list but in the expanded list it has this for F06.
Door lock fails to close / open, doorlock PTC triac open/ closed, mains frequency signal fault, mains power signal fault.
– Check for water leaks that may affect connectors J004 or J11
(three-phase) causing the relative contacts to short;
– Check Door lock terminal board (any problems due to
aggression caused by manufacturing chemical residues that may
cause short circuits);
– Check J004 / door lock wiring;
– Check door lock;
– Renew PCB.