Home › Forums › Public Support Forums › Help And Support › Fridge And Freezer Forum › Diplomat 60/40 fridge freezer not cooling
- This topic has 12 replies, 2 voices, and was last updated 13 years, 10 months ago by
b21playa.
-
AuthorPosts
-
May 21, 2012 at 7:48 pm #69589
b21playa
ParticipantHi all
I have a diplomat built in fridge freezer purchased from MFI about 4years agoh
Realised yesterday the stuff in the fridge had gone off and realised it was as the fridge was warm. At this point freezer looked ok.
I could not hear the compressor but after turning thermostat up, and messing about with it, it seems to have kicked in. Since it has stopped again
Can anyone provide any help?
Thanks in advance
May 21, 2012 at 10:36 pm #375307SAMURI
ParticipantRe: Diplomat 60/40 fridge freezer not cooling
I will need the model number to advise
Bob
September 15, 2012 at 1:15 pm #375308b21playa
ParticipantRe: Diplomat 60/40 fridge freezer not cooling
#hi
Just taken out fridge, but can not see model number
September 15, 2012 at 1:58 pm #375309SAMURI
ParticipantRe: Diplomat 60/40 fridge freezer not cooling
The model number should be inside the fridge compartment.
Normaly on a label to the left or right you should see it if you take out the salad box’s
Bob
September 15, 2012 at 2:29 pm #375310b21playa
ParticipantRe: Diplomat 60/40 fridge freezer not cooling
SAMURI wrote:The model number should be inside the fridge compartment.
Normaly on a label to the left or right you should see it if you take out the salad box’s
Bob
Ah ha……found it
Apm6012
20072908060 – 038103005 – 03September 15, 2012 at 10:05 pm #375311SAMURI
ParticipantRe: Diplomat 60/40 fridge freezer not cooling
The most likely fault will be the electronic module.
It is Unlikly to be any other fault on this model.
If you fit a new module make sure you have It set to maximum before turning the power back on otherwise you may think it is not working.
If you turn the module on after the power it has a delay of about 10 minutes before it will start
Bob
September 16, 2012 at 4:56 am #375312b21playa
ParticipantRe: Diplomat 60/40 fridge freezer not cooling
SAMURI wrote:The most likely fault will be the electronic module.
It is Unlikly to be any other fault on this model.
If you fit a new module make sure you have It set to maximum before turning the power back on otherwise you may think it is not working.
If you turn the module on after the power it has a delay of about 10 minutes before it will start
Bob
Where can I get the module from and how much are they?September 16, 2012 at 9:41 am #375313SAMURI
ParticipantRe: Diplomat 60/40 fridge freezer not cooling
From the white goods shop on this site not sure of the price.
If not then post again and I will give you another supplier.
BobSeptember 16, 2012 at 10:04 am #375314b21playa
ParticipantRe: Diplomat 60/40 fridge freezer not cooling
SAMURI wrote:From the white goods shop on this site not sure of the price.
If not then post again and I will give you another supplier.
BobAt £85 an expensive part
September 17, 2012 at 9:37 pm #375315b21playa
ParticipantRe: Diplomat 60/40 fridge freezer not cooling
What goes wrong with the electronics module?
September 24, 2012 at 12:16 pm #375316b21playa
ParticipantRe: Diplomat 60/40 fridge freezer not cooling
could it be the thermistor on the pcb?
September 26, 2012 at 7:49 pm #375317b21playa
ParticipantRe: Diplomat 60/40 fridge freezer not cooling
Managed to get a digital thermometer to check the temp
The freezer was -16.5deg and the fridge was +11deg.
December 2, 2012 at 4:29 pm #375318b21playa
ParticipantRe: Diplomat 60/40 fridge freezer not cooling
Model: apm6012
Freezer is cold, but fridge sometime gets down to 4deg, other times 12-16deg
Where is the hole/fan when the cold from freezer is circulated to fridge
-
AuthorPosts
- You must be logged in to reply to this topic.