necht cut out

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #69824
    Devlin Maguire
    Participant

    I have a necht wqp12 -9319, not heating, element heats with remote power, and there is 240V at the element live and earth not at the Neutral, cutout is passing current ok, now there is another componant that looks like a stat but has live (pink) and neutral terminals is this another cut out and if so whats it purpose Thanks
    Dev

    #376108
    kwatt
    Keymaster

    Re: necht cut out

    All about Necht

    Basically, there’s no service or spare parts info on these at all unless one of the guys happens to now the dishwasher through seeing one before. It’s probably a Chinese Midea or Haeir but, goodness knows.

    K.

    #376109
    Devlin Maguire
    Participant

    Re: necht cut out

    On further investigation it appears that the second thermal cut out breaks the neutral why they would do this is anyones guess I am going the bypass this and see if I get the element to work
    I have bunged it in the freezer for the time being maybe it’ll reset
    Dev

    #376110
    admin
    Keymaster

    Re: necht cut out

    Hi

    This would more likely be a pressure switch which would stop the unit heating if there was not enough pressure to operate the unit correctly.
    If you send me a photo to samsung@ffrservices.co.uk i will confirm it or not.

    Bryan

    #376111
    Devlin Maguire
    Participant

    Re: necht cut out

    It is definatly a ksd201 stat there are 2 of them at differant places on the element there is also what I assume is a thermistor up into the controller right on the bottm of the eash tank it looks as if it should be glued with some sort of thermal paste and it has come adrift, I am getting current to the element now but the power to the elment does’nt stay on very long but this might be becuase the tank water level in never that high any making progress
    Dev

    #376112
    admin
    Keymaster

    Re: necht cut out

    Hi

    Putting in the freezer is a waste of time..It won’t reset if its a thermal cutout.

    bryan

    #376113
    Devlin Maguire
    Participant

    Re: necht cut out

    Thought as much Bryan after 2 hours it’s still open any way they are available as a pair one is re-setable at one aint got them on fleabay