ELECTROLUX INSPIRE W/M EWM14780W. PROD 914527306 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › ELECTROLUX INSPIRE W/M EWM14780W. PROD 914527306 This topic has 4 replies, 4 voices, and was last updated 13 years, 9 months ago by richardable. Viewing 5 posts - 1 through 5 (of 5 total) Author Posts June 27, 2012 at 7:47 am #70166 richardableParticipant reported fault w/m will only drain. checked vsrious programs and the w/m would only drain. customer said her son was seen pushing various buttons whilst the machine was running ( possibly on the spin cycle) is there a reset available? June 27, 2012 at 8:32 pm #377252 SeamyParticipant Re: ELECTROLUX INSPIRE W/M EWM14780W. PROD 914527306 If you go into service mode & check last fault code, post back, likely once you go in & come out of service mode it will reset. June 27, 2012 at 8:51 pm #377253 A1engineerParticipant Re: ELECTROLUX INSPIRE W/M EWM14780W. PROD 914527306 usually this is to do with the new type pressure sensors, as seamy says a reset usually fixes it, if not try tapping the P/S and trying again, last resort new switch. June 28, 2012 at 6:23 am #377254 richardableParticipant Re: ELECTROLUX INSPIRE W/M EWM14780W. PROD 914527306 thanks guys how do i get into service mode? richard able June 28, 2012 at 1:35 pm #377255 timdowningParticipant Re: ELECTROLUX INSPIRE W/M EWM14780W. PROD 914527306 Just taking the pressure switch tube off is normally enough to right things. Author Posts Viewing 5 posts - 1 through 5 (of 5 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In