    Muv
    Participant

    Hi all

    Got one of these horrible dryers to do, machine works fine, apart from no heat..

    Does the small PCB have anything to do with the heater?or is this controlled via the timer.

    But he way it’s the vented type

    Martin

    #379931
    Criscold
    Participant

    Re: Hoover HNC 160-80

    No the small board is the start relay board, go for the element probably one of the stats but these are not available as as spare on their own so would be element only

    Colin

    #379932
    Muv
    Participant

    Re: Hoover HNC 160-80

    Thanks Colin

    Element,and stats, all checkout ok (forgot to mention that in previous post)

    Martin

    #379933
    Criscold
    Participant

    Re: Hoover HNC 160-80

    Sorry I don’t know this or have any info on the 160, on the 170 it shows the heater being fed via the exhaust stat they look very similar models and can let you have more info on that one

    Colin

    #379934
    Muv
    Participant

    Re: Hoover HNC 160-80

    Thanks Colin..will pm you my email…

    Martin

    #379935
    Muv
    Participant

    Re: Hoover HNC 160-80

    Turns out it is the thermostat on the exhaust, but looks like these are not available..
    It’s marked as 85 dg C..anyone know where to get them..

    Martin

    #379936
    Criscold
    Participant

    Re: Hoover HNC 160-80

    Both Connect and Qualtex list them as HVR09201212 about £10-00 +

    #379937
    Muv
    Participant

    Re: Hoover HNC 160-80

    Thanks Colin… Had item today, and dryer now upand running again..


    Martin

Viewing 8 posts - 1 through 8 (of 8 total)