hotpoint wmf940 no motor action

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries hotpoint wmf940 no motor action

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #71249
    AASWALES
    Participant

    hi the above machine has no motor action and is displaying no error codes , the motor is induction type but i cannot find a capacitor in the machine ?

    thanks

    alan

    #380459
    Seamy
    Participant

    Re: hotpoint wmf940 no motor action

    Check wiring between motor control unit & motor, motor control unit & control board, also check windings of motor. Normally they throw up a fault code like F06 if theres no signal back from tacho.

    #380460
    Hollytree_Technical
    Participant

    Re: hotpoint wmf940 no motor action

    Note that this is a 3 phase induction motor, therefore it does not need a motor start capacitor, it will have three windings connected in delta (triangular) configuration, this means that you should get exactly the same readings between any 2 of the winding connections. It may be worth taking the main module out and having a good look at it as I have seen a few of these which have gone pop.

    Jem

    #380461
    rocker
    Participant

    Re: hotpoint wmf940 no motor action

    Thanks gents, for your advice will look into this. john

    #380462
    AASWALES
    Participant

    Re: hotpoint wmf940 no motor action

    Cheers for the info will take a look at the module ,

    Thanks again

    Alan