Aqualtis AQ113D697E constant pumping out

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Aqualtis AQ113D697E constant pumping out

Viewing 8 posts - 1 through 8 (of 8 total)
  • Author
    Posts
  • #71886
    a1al
    Participant

    Hi everyone
    Been out to this washing machine it would do nothing but pump out.
    I changed the main module and it done a 30min quick wash while I was there. Customer rang next day to say that it was only pumping out again.

    Any ideas anyone??

    Alymer

    #382690
    a1al
    Participant

    Re: Aqualtis AQ113D697E constant pumping out

    Sorry meant to mention that it does not show any fault codes that I can see.
    Thanks

    #382691
    Muv
    Participant

    Re: Aqualtis AQ113D697E constant pumping out

    Sounds like it could be a dodgy pressure switch

    Martin

    #382692
    a1al
    Participant

    Re: Aqualtis AQ113D697E constant pumping out

    Hi Martin
    Does a new pressure switch need to be reset as I’ve read in some posts?
    Alymer

    #382693
    Muv
    Participant

    Re: Aqualtis AQ113D697E constant pumping out

    I’ve never had to do the reset procedure after putting a new switch in…I think that’s only applicable if you have had to clean out the filter/pump, and the machine has been layed flat down on either its back, or sides, this lets water run up tube and in to switch…

    Or so I believe….unless anyone knows different?

    Martin

    #382694
    madangler1
    Participant

    Re: Aqualtis AQ113D697E constant pumping out

    Has it got the linear pressure switch ?

    If so it thinks there is water in it. Iv seen these pump for about 45 minutes then throw F05. But if it was not left that long no error was shown.

    Did you check the sump? One had a blockage (sock) in the sump. In the other a cable tie manage to float up into the pressure hose rite at the bottom.

    #382695
    a1al
    Participant

    Re: Aqualtis AQ113D697E constant pumping out

    What do you mean by a linear pressure switch?
    The one fitted to this machine is blue in colour and has 4 wires connected to it by edge connector.

    #382696
    madangler1
    Participant

    Re: Aqualtis AQ113D697E constant pumping out

    Yep that’s linear switch, measures actual water quantity via pressure rather than just a set level.

    I would check the sump and pressure system then perform a reset as per HP method

Viewing 8 posts - 1 through 8 (of 8 total)