November 2, 2012 at 8:19 pm #72312
deltra
Participanthi all, customer said dryer was noisy and no heat! went out , unblocked fan at front left(cured noise)element o/c. got replacement element and two heater stats(135+150) also fan chamber ntc. fitted all these bits, machine worked a treat 😀 for 2 loads. now the machine runs for 2 mins, then kills power 😕 cools (i here a stat click)then runs again 2 mins, try it on the air dry cycle (cool) its ok!!!! tried pcb, still cuts out, all channels are clear, filter and fan ok,whats going on :clown: have i put stats in wrong way? does overheat stat kill power? i have i squashed a pixie? any help, drawings? cant get dvd to load………. am i being a…… :clown:
November 2, 2012 at 8:27 pm #384138kwatt
KeymasterRe: dv06 dryer
Does sound like the stats are in the wrong way around or, there’s condensation in it causing it to trip.
Yes, the overheat will stop it dead.
K.
November 2, 2012 at 8:42 pm #384139deltra
ParticipantRe: dv06 dryer
hi ken, looking from the backis the 150 on left ? no condensation?(i did try them other way, just same)cant see why it should be overheating,possibly new stat faulty?
November 2, 2012 at 8:45 pm #384140kwatt
KeymasterRe: dv06 dryer
Can’t recall but someone did the same a while back and got the same result.
I’d have to check it when in the office for you. Unless some kind soul happens to know in the interim.
K.
November 2, 2012 at 8:48 pm #384141deltra
ParticipantRe: dv06 dryer
cheers
November 5, 2012 at 9:06 pm #384142deltra
ParticipantRe: dv06 dryer
ken, could you have a look when your back, please, thanks.
November 10, 2012 at 8:22 pm #384143deltra
ParticipantRe: dv06 dryer
ran ok twice, now tripping again
November 10, 2012 at 8:51 pm #384144kwatt
KeymasterRe: dv06 dryer
Gotta be blocked or have something causing it to happen but I’ve never heard of any real issues with a condenser never mind the vented dryer, there’s nothing in it really.
The only issues you get are condensation, top problem especially at this time of the year and there’s booger all we can do about that.
Blockages in general.
Usual people breaking things that they shouldn’t, extremely common in commercial premises.
Broken belts/rollers: overloading generally.
But TBH, we just don’t get issues with the vented dryers, like I think this is maybe the second call on them in all the time they’ve been out there.
K.
November 10, 2012 at 9:26 pm #384145deltra
ParticipantRe: dv06 dryer
thanks ken, i ll check about condensation, still not sure which way stats are!!
November 10, 2012 at 9:45 pm #384146timdowning
ParticipantRe: dv06 dryer
Srange I’ve been meaning to post on here for some time re an ISE10 condenser (outside warranty) where it cuts out after about 15 minutes when on high heat dry, cools for a bit then comes back to life. By chance the customer found it works perfectly if low heat selected on sensor or timed.
November 10, 2012 at 11:14 pm #384147kwatt
KeymasterRe: dv06 dryer
That’s a new one Tim.
Does it give any error or shutdown completely?
K.
November 11, 2012 at 7:11 am #384148timdowning
ParticipantRe: dv06 dryer
The machine goes completely dead, no lights nothing, as if the door had been opened.
I thought I had cured it by poking around with the door switch but the poking around coincided with the time it needed to calm down.
Ta.November 11, 2012 at 10:16 am #384149kwatt
KeymasterRe: dv06 dryer
Yup, that’s an overheat shutdown, it will do that if it trips the overheat stat.
K.
November 11, 2012 at 12:50 pm #384150timdowning
ParticipantRe: dv06 dryer
Whats the recommended action for that fault? Do you want me to throw a module, heater, ntc’s, stat’s & a pump at it? Only joking…I know, not funny at all.
🙂November 11, 2012 at 1:45 pm #384151kwatt
KeymasterRe: dv06 dryer
99/100 it’s a blockage.
K.
-